QSRN Series Safety Relay Module
The QSRN safety relay module meets the safety requirements of EN/IS013849-1Cat.4 and is suitable for monitoring various signals in industrial sites with high safety requirements - including emergency stop signals, safety door switch signals, safety light barrier signals, and safety light curtain signals. Outside the two-hand button signal.
- Forced guidance of the relay contacts makes monitoring more efficient and safer.
- QSRN has a smaller external size and is pluggable for easy installation.
- QSRN has 3 normally open, 1 normally closed, a total of 4 sets of control output signals, and the control ability is stronger.
QSRN - Two-Way Transistor Signal Monitoring
- Monitor two transistor signals - power off switch, safety light barrier, etc.
- With the peripheral circuit, the monitoring of the two normally closed switch signals can also be realized.
- Full loop self-test, lock when the two signals are inconsistent.
- It has a wider applicability to the residual voltage of the grating signal, and it can work stably when the residual voltage is greater than 10V.
- It can monitor NPN signal and PNP signal, and has stronger adaptability.
- Automatic, manual reset is adjustable. In the manual reset mode, the reset button can be detected, a single reset is forced, and the next reset operation can be performed after the reset button is turned off.
QSRN - Two-Way Normally Closed Switch Monitoring
- Monitor two normally closed switch signals - emergency stop button, safety door switch, etc.
- Monitor the short circuit between the two signals.
- Short circuit to any single switch, open circuit monitoring, lock when the switch is inconsistent.
- Automatic, manual reset is adjustable. In the manual reset mode, the reset button can be detected, a single reset is forced, and the reset button must be turned off before the next reset operation.
QSRP- Two-Hand Button Monitoring
- Monitor two-hand button signal
- The button signal is detected once, and when the two-hand button triggers the time difference greater than 0.5S, w it is regarded as an invalid trigger.
- Independent dual-loop operation, full-loop self-test, lock when the two signals are inconsistent.
Technical Parameter
Safety Control Level | Level 4 |
supply voltage | DC24V ± 10% |
Power waste | ≤3W |
Load function | AC 15 : 5A/250V |
DC 13 : 6A/24V | |
Protection level | I P50 |
Response time | < 15 ms |
Ambient temperature | -10 - 55°C |
Ambient humidity | 35% ~ 95%R H |
Dielectric strength | AC 1500V, 60S (No breakdown or flashover) |
Relay life | .≥1 million times |
Outline size | 117 x 100 x 22.5 |